Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Note

You need at least aggregator version 1.1 to use this configuration.

Configuration Overview

The following configuration options of the common machine configuration model applies to Carbon3D machines:

Configuration

Data

Descripton

Mandatory

type

Carbon3d

The machines interface type

x

url

http://192.168.2.47:5000/

The individual machines interface url

x

custom_name

my_carbon3d_machine

The custom machine name will be displayed in MES together with the machine url.

x

authentication_file_path

./secret.json

The secret.json for JWT authentication.

x

mes_id

[10, 33]

The MES instance(s) of your organization.

x

umati_server_port

4840+

To specify umati server port used for data transfer between aggregator and the machine driver.

optional

Carbon3D machine example:

Code Block
breakoutModewide
{
     "type": "MTCONNECT",
     "url": "http://192.168.2.47:5000",
     "custom_name": "my_carbon3d_machine",
     "authentication_file_path": "./secret.json",
     "mes_id": [
        10,
        33
      ]
    }

...